Total Dissolved Solids (TDS), Electrical Conductivity (EC), dan pH sebagai Indikasi Awal Keterdapatan Pencemar pada Air
DOI:
https://doi.org/10.29303/goescienceed.v6i4.1272Keywords:
Water, Nitrate, TDS, EC, pHAbstract
Water is highly susceptible to contamination from anthropogenic factors, particularly in river water and shallow groundwater located in densely populated residential areas such as the study site. The research area is situated around the Winongo River, covering parts of Tegalrejo, Pringgokusuman, Pakuncen, and Ngampilan sub-districts in Yogyakarta City, D.I.Y. Studies on water quality are generally conducted through field measurements and water sampling. However, when water sampling is not carried out simultaneously with field measurements, the process becomes inefficient and increases the risk of laboratory test results not accurately representing actual environmental conditions. Therefore, this study aims to demonstrate that Total Dissolved Solids (TDS), Electrical Conductivity (EC), and pH can serve as preliminary indicators of the presence of pollutants, particularly ionic contaminants. The analysis was conducted through qualitative correlation using mapping and quantitative correlation between pH, TDS, and EC with nitrate concentration using Spearman’s correlation test. The results show that TDS and EC exhibit a strong correlation with nitrate levels. This is because nitrate is highly soluble and consists of ionic bonds that can move freely in solution. In contrast, pH also shows a correlation with nitrate but not as strong as TDS and EC, since pH does not directly detect nitrate ions. Therefore, TDS and EC can be effectively used as early indicators of contamination, especially for pollutants containing ionic bonds.
References
Anonim. (2023). Informasi kinerja pengelolaan lingkungan hidup daerah. Kota Yogyakarta: Dinas Lingkungan Hidup Daerah Kota Yogyakarta.
Badan Perencanaan Pembangunan, Riset, dan Inovasi Daerah D.I.Y. (2023). Data statistik penduduk. Diakses dari https://bapperida.jogjaprov.go.id/dataku/data_dasar/index/701-penduduk?id_skpd=177
Fitts, C. R. (2002). Groundwater science. California, USA: Academic Press.
Hendrayana, H. (2016, Oktober). Cekungan air tanah Yogyakarta–Sleman: Potensi, pemanfaatan dan pengelolaan air tanah. Paper dipresentasikan pada Workshop Nasional Asia Pacific Centre for Ecohydrology (APCE), Yogyakarta, Indonesia.
Manny, L., Atmaja, R. R., & Putra, D. P. E. (2016). Groundwater level changes in shallow aquifer of Yogyakarta City, Indonesia: Distribution and causes. Journal of Applied Geology, 1(2), 88–99. https://doi.org/10.22146/jag.27584
Muhid, A., & Hidayat, D. N. (Eds.). (2019). Analisis statistik: 5 langkah praktis analisis statistik dengan SPSS for Windows. Sidoarjo, Indonesia: Zifatama Jawara.
Mukarromah, R. (2016). Analisis sifat fisis dalam studi kualitas air di mata air Sumber Asem Dusun Kalijeruk, Desa Siwuran, Kecamatan Garung, Kabupaten Wonosobo (Skripsi tidak diterbitkan). Universitas Negeri Semarang, Indonesia.
Nolan, B. T., & Hitt, K. J. (2006). Vulnerability of shallow groundwater and drinking water wells to nitrate in the United States. Environmental Science & Technology, 40(24), 7834–7840. https://doi.org/10.1021/es060911u
Peraturan Gubernur Daerah Istimewa Yogyakarta No. 20 Tahun 2008 tentang Baku Mutu Air D.I. Provinsi Daerah Istimewa Yogyakarta. Badan Pengendalian Dampak Lingkungan Daerah Provinsi DIY.
Putra, G. Z. M. (2016). Hubungan hidrolika antara air tanah dan air sungai Ciujung serta dampaknya terhadap kualitas air tanah di sekitar Desa Kragilan, Kecamatan Kragilan, Kabupaten Serang, Provinsi Banten (Skripsi tidak diterbitkan). Universitas Gadjah Mada, Indonesia.
Reza, K. (2021). Penentuan status mutu air Sungai Winongo dan Sungai Gajahwong pada parameter fosfat, nitrat, dan amonia menggunakan metode Storet, Indeks Pencemaran, CCMEWQI, dan BCWQI (Skripsi tidak diterbitkan). Universitas Islam Indonesia, Indonesia.
Rozi, A. F., & Saves, F. (2024). Karakteristik air tanah berdasarkan sifat fisik: Studi kasus Kelurahan Keputih, Kecamatan Sukolilo. Indonesian Journal of Civil Engineering Education, 10(2), 55–62. https://doi.org/10.20961/ijcee.v10i2.95033
Ruseffandi, M. A., & Gusman, M. (2020). Pemetaan kualitas air tanah berdasarkan parameter total dissolved solids (TDS) dan daya hantar listrik (DHL) dengan metode ordinary krigging di Kec. Padang Barat, Kota Padang, Provinsi Sumatera Barat. Buletin Teknik, 5(1), 153–162. https://doi.org/10.24036/bt.v5i1.107631
Satapona, A. (2018). Pemodelan aliran airtanah kawasan Malioboro dan sekitarnya (Tesis tidak diterbitkan). Universitas Gadjah Mada, Indonesia.
Todd, D. K., & Mays, L. W. (2005). Groundwater hydrology (3rd ed.). USA: John Wiley & Sons, Inc.
Toruan, P. L., Rahmawati, & Setiawan, A. A. (2022). Konduktivitas listrik ion terlarut: Studi kasus air sumur TPA Sukawanitan Palembang. Jurnal Redoks, 7(1), 48–54. https://doi.org/10.31851/redoks.v7i1.6760
Winter, T. C., Harvey, J. W., Franke, O. L., & Alley, W. M. (1998). Groundwater and surface water. Colorado, USA: U.S. Geological Survey.
Yogafanny, E. (2015). Pengaruh aktivitas warga di sempadan sungai terhadap kualitas air Sungai Winongo. Jurnal Sains dan Teknologi Lingkungan, 7(1), 41–50. https://doi.org/10.20885/jstl.vol7.iss1.art3
Zahra, F. S., Putranto, T. T., & Muhammad, F. (2021). Penilaian kualitas air tanah untuk air minum dan air irigasi di Kota Banjarbaru dan sekitarnya. Jurnal Geosains dan Teknologi, 4(2), 57–71. https://doi.org/10.14710/jgt.4.2.2021.57-71